<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>45042</ErrorNumber>
<ErrorFamily>Exposure Head Interface</ErrorFamily>
<ErrorMessage>
EHI: shutdown of thermal head due to temperature or humidity alarm
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Every thirty seconds, the thermal head firmware reads the case temperature,
ambient temperature and humidity sensors and compares the reading to the
appropriate threshholds.  If any threshhold has been exceeded, the thermal
head is shutdown and any plot in progress is aborted.  This error code indicates
an alarm condition.
</text></DescriptionText>
<DescriptionText><text>
This error code applies to Thermal Head firmware version 1.30 and above.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Verify the temperature and humidity of the environment local to the machine.
</Cause>
<Cause>
Check the thermal head cooling ( thermal heads are air-cooled or water-cooled ).
Is the water-cooling functioning?
</Cause>
<LastModified>
03-Jul-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../prm/ehi_head_casehigh.xml</LinkAddress><LinkTitle>PRM: head casehigh</LinkTitle></Link>
<Link><LinkAddress>../prm/ehi_head_caselow.xml</LinkAddress><LinkTitle>PRM: head caselow</LinkTitle></Link>
<Link><LinkAddress>../prm/ehi_head_humidity.xml</LinkAddress><LinkTitle>PRM: head humidity</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:44 2008 PST
</Updated>
<Links>
</Links>
</Error>